A bathtub has the same valve as a sink and a different set of parts around it. The spout is larger, the diverter is built into it, and the whole assembly sees more water, more heat and more load than a vanity tap. The result is a set of faults that are easy to recognise and often easy to fix, provided the right part is identified.
The spout that drips at the wall
Water at the wall rather than at the opening is the spout's own connection failing. A slip-fit spout with a set screw seals on an O-ring around the pipe; a threaded spout seals on the threads. When the O-ring hardens, water tracks back along the pipe and appears where the pipe meets the wall, often at the floor below.
This is the fault most often misdiagnosed as a valve problem, because the drip appears far from the valve and only when the water runs.
The diverter
Two arrangements exist. On a spout with an integrated diverter, the spout is the assembly: a gate or plunger inside it redirects water to the shower, and when it fails the spout keeps running while the shower is on. The usual fix is a new spout, sized to the pipe.
On a valve with a separate diverter handle, the diverter is a third valve with its own stem and seat, and it can be renewed like any compression valve.
The valve itself
Two-handle tub valves are compression fittings, and they fail the way all compression fittings fail: a hardened washer, a pitted seat, or a stem O-ring that lets water out at the handle. A single-handle tub valve is usually the same cartridge family as the shower valve it shares a wall with.
Access is the constraint. Under a tub there is often no panel, and the valve is reached from the front through the trim, or from an adjacent closet or wall.
Scale and heat
A tub filler runs hot water more often than a sink tap and sits in a wet environment, so scale builds where water stands. That is why diverters seize and spouts drip at the joint rather than at the opening.
Where the water is hard, the practical result is that a repair which ignores the seating surface returns. La Mirada's supply is hard at roughly ten grains per gallon on a regional estimate, and the neighbouring cities report higher figures on their own water quality reports.
Repair or replace
O-rings, washers, seats, stems and separate diverters are repairs. An integrated-diverter spout is a replacement part by design. A cracked valve body or a rough-in that has corroded through is a bigger job, and it is worth knowing before the wall is opened.