A tub filler does two jobs with one body: it fills the tub and it diverts water to the shower. At La Habra's 16 grains per gallon, the diverter's moving parts collect scale faster than the valve, which is why a tub that will not switch cleanly is a common complaint here.
When the water appears
Handles closed and water still falling from the spout mean the valve is passing. While the tub fills, water at the wall plate is the spout joint. Only while the shower runs, water continuing from the tub outlet is the diverter.
Water can travel inside a wall, so a leak that shows on the floor below may originate at the spout plate rather than the valve.
The diverter
An integrated-diverter spout holds a gate or plunger that redirects flow. Scale and hardened seals keep it from closing fully, so water keeps running into the tub and shower pressure drops.
A separate diverter handle is a third compression valve, with its own stem and seat, and it can be rebuilt. Scale on its stem is the usual reason it becomes stiff.
The spout joint
A slip-fit spout pushes onto a copper stub, with an O-ring for sealing and a set screw below for retention. A threaded spout seals at its threads.
A spout that has pulled away from the wall is usually slip-fit, and the stub behind it should be checked before a new spout is fitted.
The valve
Older fillers are commonly two-handle compression fittings, with washers, seats and stem packing. Single-handle fillers use a cartridge.
The valve sits behind the wall or below the deck, and access is the cost that decides the job. A deck-mounted filler may be reached through a panel, a closet or the room below; a wall-mounted one is reached through the trim.
Hard water and the valve seat
A seat that has scaled or pitted will cut a new washer into the same shape. Cleaning and dressing the seat belongs in the repair, not after it.
Permits and shutoff
Where opening the wall or deck moves the work into alteration, La Habra's Building & Safety counter decides the permit through its counter or online portal. With no fixture stop on most tubs, the property main is the shutoff, and the water supplier named on the bill is the contact if a meter valve will not close.
Repair or replacement
A washer, seat, stem, spout O-ring or separate diverter can be renewed. A spout with an integrated diverter cannot be rebuilt, so it is renewed as one piece. A cracked body means a new valve.