Not every faucet has a cartridge. Two-handle taps and many older single-handle fixtures rely on a valve made of a stem, a seat and a washer, or a ball with spring-loaded seats, or a pair of ceramic plates. Each design fails in its own way and each is repaired with different parts.
Compression valves
The classic two-handle tap uses a stem that screws down onto a rubber washer, pressing it against a brass seat. Closing the tap compresses the washer; opening it lifts the stem away.
The washer takes the wear, but the seat takes the damage. Mineral scale and grit pit the seat, and a new washer pressed against a pitted seat is cut into the same shape within weeks. That is why a tap can be "fixed" every few months and never stop dripping. Dressing the seat, or replacing it, is the step that ends the cycle.
Ball valves
A single-handle ball faucet uses a slotted ball with spring-loaded rubber seats and a cam. A drip with the handle closed is usually the seats or springs; a stiff or loose handle is the cam and packing. The parts are small and easy to lose, which makes a kit the practical purchase.
Ceramic-disc valves
A ceramic-disc valve uses two plates with ports cut into them; rotating one against the other opens and closes the flow. The plates are hard and long-lived, so when the faucet drips the fault is usually a seal around the cartridge or debris caught between the discs. A disc that has cracked or chipped cannot be repaired and the cartridge is replaced.
Stems, packing and handles
A stem that has worn at the threads will not hold a setting, and a stem that has corroded can seize. Packing or an O-ring around the stem is what stops water escaping at the handle; when it fails, water appears at the base of the handle while the valve itself still shuts.
A handle that has stripped its splines will turn without moving the stem, which is a handle or stem problem rather than a valve problem.
When a valve is beyond repair
A body with a cracked port, a seat that has been cut so deep that dressing removes the sealing surface, a ball chamber that has corroded through, or a stem no longer manufactured. At that point the fixture is replaced, and older two-handle sets are the usual candidates.
The visit
The supply is isolated at the fixture stops, or at the main if a stop has failed. The handle comes off, the stem or cartridge is withdrawn, the seat and body are inspected, and the replacement parts are fitted with the bore cleaned of scale. A valve that is repaired with a sound seat lasts; one repaired around a damaged seat does not.