A single-handle tap keeps all of its valving in one removable element. When that element stops sealing, the tap drips at the spout, and the repair is a part rather than a fixture, provided the right part can be found.
Identifying what is inside
The cartridge is matched to the body by dimensions and port layout, and two taps that look alike from the counter can take different ones.
Three things settle it: the tap's brand and model, the handle's fixing type, and any number moulded into the old cartridge. A photograph of the spout rarely helps, because the shape that matters is hidden inside the body.
Where a tap has no visible branding, the old cartridge is the only reliable key, which means it comes out before the replacement is ordered.
Which valve family
A ceramic disc cartridge uses two plates that slide across each other. A plastic cartridge turns a barrel with O-rings. A compression stem, common on older two-handle taps, is a washer and seat arrangement and not a cartridge at all.
Getting this wrong means buying a part that cannot fit, so it is worth checking before the tap comes apart.
The bore under the cartridge
The cartridge sits in a machined bore, and that bore is where deposits collect. On this corridor the water supplier varies by street and no system-wide hardness reading was verified, so the condition of the bore has to be read from the tap itself rather than assumed from an address.
A bore with a film on its walls will make a new cartridge drag. Cleaning it, and checking the bore's edge for roughness, is part of the replacement.
Symptoms worth acting on
- Water at the spout after the handle is closed.
- A handle that has stiffened through its travel.
- Temperature that drifts on a mixing cartridge.
- A tap that has to be forced shut.
Water at the base of the tap or under the cabinet is a different fault, usually an O-ring, a supply connection or a drain part.
Shutoff before the part comes out
The stops beneath the sink are the first check. A stop that closes fully makes this a small job; one that will not close makes it a shutoff for the unit, and on a property with a shared supply the neighbour may need notice.
Discontinued and obsolete
Older taps are the hard case. If the cartridge has been discontinued and no equivalent is listed, the choices are a rebuild kit, a compatible aftermarket part of identical dimensions, or a new tap.
An aftermarket part that is close but not identical will either bind or weep, and that outcome costs more than the fixture it was meant to save.
When replacement beats repair
A tap with a cracked body, a stripped handle spline or a body that no longer holds a cartridge is finished as a repair. The deck holes then decide what can go back in its place.